Cominfo AWZ333
External power supply for turnstile with MT drive unit - indoor installation
230VAC/12VDC, 3A
Operation temperature: 10°… +30°C
230VAC/12VDC, 3A
Operation temperature: 10°… +30°C
PSU type | A (EPS - External Power Source), | |||
protection class 1÷2, II environmental class | ||||
Mains supply | 230V/AC 50Hz (-15%/+10%) | |||
Current consumption | 0,42A @230V AC | |||
PSU power | 42W | |||
Output voltage | 11V÷ 13,8V DC – buffer operation | |||
10V÷ 13,8V DC – battery-assisted operation | ||||
Output current | - for grades 1, 2: | |||
Io = 1,4A + 0,9A battery charging current | ||||
- for general use: | ||||
Io = 3A (without a battery) | ||||
Io = 2,6A + 0,4A battery charging current | ||||
Io = 2,1A + 0,9A battery charging current | ||||
Output voltage adjustment range | 11÷14,5V DC | |||
Ripple voltage | 20mVp-p | |||
Battery charging current | 0,4A/0,9A jumper selectable | |||
Short-circuit protection SCP | 200% ÷ 250% of PSU power - current limitation and/or fuse FBAT damage | |||
in the battery circuit (fuse-element replacement required) | ||||
Automatic return | ||||
Overload protection OLP | 110% ÷ 150% (@25ºC÷65ºC) of PSU power - limitation by the PTC | |||
resettable fuse, manual restart (disconnection of the DC output circuit) | ||||
U>16,5V disconnection of the output voltage (AUX+ disconnection), | ||||
Overvoltage protection OVP | automatic return | |||
U> 14,5V fault indication | ||||
Battery circuit protection SCP and reverse | F5A- current limitation, FBAT fuse (in case of a failure, fuse-element | |||
polarity connection | replacement required) | |||
Deep discharge battery protection UVP | U<10V (± 0,5V) – disconnection of battery terminal | |||
Tamper protection: | ||||
- TAMPER - indicates unwanted opening of | - microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) | |||
the enclosure | ||||
Technical outputs: | ||||
- EPS; output indicating AC power failure | - OC type: 50mA max. | |||
Normal operation: L state (0V), | ||||
failure: hi-Z state, | ||||
- delay time 0s÷1h (+/-20%) – jumper selectable TAC | ||||
- PSU; output indicating no DC power/PSU | - OC type: 50mA max. | |||
failure | Normal operation: L state (0V), | |||
failure: hi-Z state, | ||||
- APS; output indicating battery failure | - OC type, 50mA max. | |||
Normal operation: L state (0V), | ||||
failure: hi-Z state | ||||
LED indication | LEDs: AC/DC power status, failure | |||
Acoustic indication | piezoelectric indicator 75dB/0,3m, switchable via jumper | |||
Operating conditions | II environmental class, -10 oC÷40 oC | |||
Enclosure | Steel plate DC01, thickness: 0,7mm, colour: RAL 9003 | |||
Dimensions | W=230 H=300 D+D1=92+8 mm [+/-2 mm] | |||
W1=235, H1=305 [+/-2 mm] | ||||
Net/gross weight | 3,5 / 3,7kg | |||
Fitting battery | 17Ah/12V (SLA) max. | H | ||
180x165x85mm (WxHxD) max | W | |||
D | ||||
Closing: | Cheese head screw (at the front), | |||
Declarations, warranty | CE, 5 year from the production date | |||
Notes: | The enclosure does not adjoin the assembly surface so that cables can | |||
be led. | ||||
Convectional cooling. |